{"id":131,"date":"2017-08-03T11:29:37","date_gmt":"2017-08-03T09:29:37","guid":{"rendered":"https:\/\/medibim.com.tr\/TR\/2013\/08\/03\/biyomedikal-kalibrasyon-kapsam-ve\/"},"modified":"2023-10-20T18:38:15","modified_gmt":"2023-10-20T15:38:15","slug":"biyomedikal-kalibrasyon-kapsam","status":"publish","type":"post","link":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/","title":{"rendered":"Biyomedikal Kalibrasyon Kapsam"},"content":{"rendered":"<h2><strong><span style=\"font-size: 14pt;\">Biyomedikal Kalibrasyon Kapsam<br \/>\n<\/span><span style=\"font-size: 12pt;\">Medibim; Biyomedikal Kalibrasyon \u00d6l\u00e7\u00fcm Hizmetlerinde sekt\u00f6r\u00fcn lideri bir firma olarak,\u00a0<\/span><\/strong><\/h2>\n<h1><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-1178 size-thumbnail\" src=\"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2017\/08\/ISO-9001-1_Certified-150x150.png\" alt=\"\" width=\"150\" height=\"150\" \/><\/h1>\n<ul>\n<li>TS EN ISO standartlar\u0131<\/li>\n<li>AAPM<\/li>\n<li>IPEM<\/li>\n<li>WHO ile bu konuda s\u00fcrekli i\u015f birli\u011fi i\u00e7inde olan\u00a0ECRI INST\u0130TUTE Enstit\u00fcs\u00fcn\u00fcn,\u00a0<strong>Biomedical Benchmark,<\/strong><\/li>\n<li>Gerekti\u011fi durumlarda \u00fcretici Koruyucu bak\u0131m ve kalibrasyon prosed\u00fcrlerini baz alarak,<\/li>\n<\/ul>\n<p>cihaz \u00f6l\u00e7\u00fcm parametrik kapasitesini tam olarak sa\u011flamakta ve m\u00fc\u015fterilerine hizmet vermektedir.<\/p>\n<p>Medibim Biyomedikal Kalibrasyon Kapsam, Periyot ve \u00d6l\u00e7\u00fcm Parametreleri a\u015fa\u011f\u0131da verilmi\u015ftir.<\/p>\n<h4><strong><span style=\"font-size: 12pt;\">Biyomedikal Kalibrasyon kapsam ve periyot s\u00fcreleri<img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-1179\" src=\"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2017\/08\/tse-e1540471920428-300x170.png\" alt=\"\" width=\"150\" height=\"85\" srcset=\"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2017\/08\/tse-e1540471920428-300x170.png 300w, https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2017\/08\/tse-e1540471920428-392x225.png 392w, https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2017\/08\/tse-e1540471920428.png 396w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/span><\/strong><\/h4>\n<p>S\u0131k\u00e7a rastlanan t\u0131bbi cihazlar\u0131n genel olarak performans testleri, deneyleri ve kalibrasyonlar\u0131na ait periyodik \u00f6l\u00e7\u00fcm ve parametre bilgileri a\u015fa\u011f\u0131daki tabloda verilmi\u015ftir..<\/p>\n<table style=\"width: 701px; border: 0px solid #07f7e8; border-width: 1px;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"314\" \/>\n<col width=\"269\" \/>\n<col width=\"118\" \/> <\/colgroup>\n<tbody>\n<tr>\n<td class=\"xl64\" width=\"314\" height=\"20\">Cihaz Ad\u0131<\/td>\n<td class=\"xl64\" width=\"269\">Kalibrasyon \u00d6l\u00e7\u00fcm Parametreleri<\/td>\n<td class=\"xl64\" width=\"118\">Periyot<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">4 KANALLI TENS C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi; Frekans, Ak\u0131m, Genlik, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">A\u00c7IK YATAK Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ALKOLMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi (Promil \u00d6l\u00e7\u00fcm)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">AMEL\u0130YAT MASASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"130\">\n<h6>AMEL\u0130YATHANE ve YO\u011eUNBAKIM TEM\u0130Z ODA VAL\u0130DASYONLARI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Hava Debi \u00d6l\u00e7\u00fcmleri, Oda Fark Bas\u0131n\u00e7 \u00d6l\u00e7\u00fcmleri,Hava Ak\u0131\u015f diyagramlar\u0131n\u0131n belirlenmesi Partik\u00fcl \u00d6l\u00e7\u00fcm\u00fc, Hava De\u011fi\u015fim Oranlar\u0131 Hesaplanmas\u0131, Hepa Filtre S\u0131zd\u0131rmazl\u0131k Testleri,Hava H\u0131zlar\u0131 \u00d6l\u00e7\u00fcm\u00fc, Ameliyathane Ortam S\u0131cakl\u0131\u011f\u0131 ve Nem \u00d6l\u00e7\u00fcm\u00fc, Ameliyathane Ayd\u0131nlanma Testleri<\/td>\n<td class=\"xl65\" width=\"118\">3 Ay \/ 6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">AMEL\u0130YAT LAMBASI LOKAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">45 derece ve 90 derece I\u015f\u0131k \u015eiddeti (Lux) \u00d6l\u00e7\u00fcmleri<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">\n<h6>ANESTEZ\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Solunum H\u0131z\u0131, Dakika Hacim, Tidal Hacim, PIF, PEF, Ak\u0131\u015f, PEEP, Insp Zaman\u0131, Exp Zaman\u0131, I:E Oran\u0131 &amp;PIP, MAP&amp; IPP&amp; FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance, Rate, Cut-off, Performans, Dinamik Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">ANJ\u0130OGRAF\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs, G\u00f6r\u00fcnt\u00fc do\u011frulama<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ANT\u0130 PN\u00d6MAT\u0130K TURN\u0130KE C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">ASP\u0130RAT\u00d6R CERRAH\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Cihaz\u0131n Ak\u0131\u015f ve Vakum \u00f6l\u00e7\u00fcmleri, Vakum Y\u00fckselme (T\u00fcm Vakum parametrelerinde), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">ASP\u0130RAT\u00d6R SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Cihaz\u0131n Ak\u0131\u015f ve Vakum \u00f6l\u00e7\u00fcmleri (T\u00fcm Vakum parametrelerinde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">ASP\u0130RAT\u00d6R SAB\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Cihaz\u0131n Ak\u0131\u015f ve Vakum \u00f6l\u00e7\u00fcmleri (T\u00fcm Vakum parametrelerinde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">A\u015eI DOLABI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">A\u015eI DOLABI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">AZOT MANOMETRE SAB\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">AZOT MANOMETRE SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BALON JOJE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BASK\u00dcL MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BASK\u00dcL D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BEBEK ISITICISI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BEBEK TERAZ\u0130S\u0130 MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BEBEK TERAZ\u0130S\u0130 D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BEDEN DERECES\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BEHER Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BENMAR\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">B\u0130OG\u00dcVENL\u0130K, KEMOTERAP\u0130, M\u0130KROB\u0130YOLOJ\u0130K G\u00dcVENL\u0130K KAB\u0130NLER\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131zd\u0131rmazl\u0131k Testi, Downflow &#8211; \u0130nflow Hava H\u0131z\u0131(m\/sn), I\u015f\u0131k \u015eiddeti, G\u00fcr\u00fclt\u00fc Testi (dB) ve Partik\u00fcl \u00d6l\u00e7\u00fcmleri<\/td>\n<td class=\"xl65\" style=\"text-align: left;\" align=\"right\" width=\"118\">6 \/ 12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"74\">\n<h6>BPAP C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Infant-Pediatric-Adult : Solunum H\u0131z\u0131, Tidal Hacim &amp;Dakika Hacim, Ak\u0131\u015f, PEEP, PIP, MAP, IPP, Insp Zaman\u0131, Exp Zaman\u0131, I:E, FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BUZDOLABI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BUZDOLABI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">BUZDOLABI TERMOMETRES\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">B\u00dcRET Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">CERRAH\u0130 M\u00dcDAHELE LAMBASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">I\u015f\u0131k \u015eiddeti (Lux)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">C KOLLU SKOP\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs, G\u00f6r\u00fcnt\u00fc do\u011frulama<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">COLDBACK KAZANI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">COLDBACK KAZANI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"74\">\n<h6>CPAP C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Infant-Pediatric-Adult : Solunum H\u0131z\u0131, Tidal Hacim &amp;Dakika Hacim, Ak\u0131\u015f, PEEP, PIP, MAP, IPP, Insp Zaman\u0131, Exp Zaman\u0131, I:E, FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">CRYO TERAP\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u00c7EKEROCAK Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Downflow &#8211; \u0130nflow Hava H\u0131z\u0131(m\/sn)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">DER\u0130N DONDURUCU MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">DER\u0130N DONDURUCU D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">\u00c7\u0130FT BA\u015eLIKLI OKS\u0130JEN MANOMETRES\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7 (T\u00fcm Bas\u0131n\u00e7 Parametrelerinde, G\u00f6stergenin birimine ba\u011fl\u0131 olarak &#8211; 24 farkl\u0131 birimde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u00c7\u0130FT KEFEL\u0130 HASSAS TERAZ\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"111\">\n<h6>DEF\u0130BR\u0130LAT\u00d6R SAB\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Enerji, \u015earj zaman\u0131, Tepe Ak\u0131m, Tepe Voltaj, Senkronize zaman\u0131, \u015eok tavsiye algoritma testi, EKG, Artifakt, Aritma, Pacemaker, Demand, Refractory periyod, Immunity Testi, ST Segment Level, O2 Saturasyonu, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">\n<h6>DEF\u0130BR\u0130LAT\u00d6R SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Enerji, \u015earj zaman\u0131, Tepe Ak\u0131m, Tepe Voltaj, Senkronize zaman\u0131, \u015eok tavsiye algoritma testi, EKG, Artifakt, Aritma, Pacemaker, Demand, Refractory periyod, Immunity Testi, ST Segment Level, O2 Saturasyonu<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">\n<h6>DEF\u0130BR\u0130LAT\u00d6R AMBULANS T\u0130P\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">Enerji, \u015earj zaman\u0131, Tepe Ak\u0131m, Tepe Voltaj, Senkronize zaman\u0131, \u015eok tavsiye algoritma testi, EKG, Artifakt, Aritma, Pacemaker, Demand, Refractory periyod, Immunity Testi, ST Segment Level, O2 Saturasyonu<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">D\u0130AD\u0130NAMI C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">D\u0130SPENSETTE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">D\u0130ST\u0130LE SU C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Conductivity, Ph<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">D\u0130\u015e RONTGEN\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">D\u0130\u015e \u00dcN\u0130T\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi, Performans Testi &amp;Lux \u00f6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">D\u0130YAL\u0130Z C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">\n<h6>DOOPLER ULTRASONOGRAF\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">T\u00fcm problar\u0131n (Konveks,Lineer,Vajinal) homojeniteleri, G\u00f6r\u00fcnt\u00fc derinli\u011fi, Uzakl\u0131k do\u011frulu\u011fu, Aksiyel ve Lateral ay\u0131rma g\u00fcc\u00fc, \u00d6l\u00fc b\u00f6lge testi ve kistik yap\u0131 g\u00f6r\u00fcnt\u00fcleme, Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ELEKTROENSEFALOGRAF\u0130 (EEG) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"74\">\n<h6>EFORLU EKG Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h6>\n<\/td>\n<td class=\"xl65\" width=\"269\">EKG, Artifakt, Aritma, ST Segment Level, Systolic, Diastolic, Rate, Cut-off, Performans, S\u0131cakl\u0131k, Invaziv Kan Bas\u0131nc\u0131, O2 Saturasyonu, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">ELEKTROKARD\u0130YOGRAF\u0130 (EKG) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">EKG, Artifakt, Aritma, ST Segment Level, Rate, Cut-off, Performans, S\u0131cakl\u0131k, Invaziv Kan Bas\u0131nc\u0131, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">EKG C\u0130HAZI EL T\u0130P\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">EKG, Artifakt, Aritma, ST Segment Level<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">EKG HOLTER Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">EKG, Artifakt, Aritma, Pacemaker, ST Segment Level<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"130\">\n<h5>EKOKARD\u0130YOGRAF\u0130 C\u0130HAZI (EKO) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h5>\n<\/td>\n<td class=\"xl65\" width=\"269\">T\u00fcm problar\u0131n (Konveks,Lineer,Vajinal) homojeniteleri, G\u00f6r\u00fcnt\u00fc derinli\u011fi, Uzakl\u0131k do\u011frulu\u011fu, Aksiyel ve Lateral ay\u0131rma g\u00fcc\u00fc, \u00d6l\u00fc b\u00f6lge testi ve kistik yap\u0131 g\u00f6r\u00fcnt\u00fcleme, Performans Testi, EKG, Artifakt, Aritma, Pacemaker, ST Segment Level, G\u00f6r\u00fcnt\u00fc performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">ELEKTROKOTER Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Cut ve Coag k\u0131s\u0131mlar\u0131, Monopolar ve bipolar \u00e7\u0131k\u0131\u015flar\u0131n RF G\u00fc\u00e7leri, RF Ka\u00e7ak ak\u0131m, REM test, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">ELEKTROM\u0130YOGRAF\u0130 C\u0130HAZI (EMG) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ELEKTROTERAP\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">EMPEDANSMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">G\u00fcr\u00fclt\u00fc Seviye \u00f6l\u00e7\u00fcm (dB)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ENFRARUJ C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ESWT C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">ET\u0130LEN OKS\u0130T GAZ STER\u0130L\u0130ZAT\u00d6R\u00dc Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">DATA Loger ile S\u0131cakl\u0131k, Bas\u0131n\u00e7, Vakum \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ET\u00dcV Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">FAKO C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">FETAL EL DOPLER\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">F\u0130Z\u0130K TEDAV\u0130 ULTRASOUND Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Watt\/Cm2 \u00d6l\u00e7\u00fcm\u00fc, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">F\u0130Z\u0130K TEDAV\u0130 VAKUM C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">FLASH OTOKLAV Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">DATA Loger ile S\u0131cakl\u0131k, Bas\u0131n\u00e7, Vakum \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">FOTOTERAP\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Uv I\u015f\u0131k \u015eiddeti \u00d6l\u00e7\u00fcm\u00fc (\u00b5w.nm.cm), G\u00fcr\u00fclt\u00fc Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">GALVAN\u0130 &#8211; FARAD\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">G\u0130RDAP KAZANI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">G\u0130RDAP KAZANI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">G\u00d6Z ULTRASON C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">HASSAS TERAZ\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"74\">\n<h5>HASTABA\u015eI MON\u0130T\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/h5>\n<\/td>\n<td class=\"xl65\" width=\"269\">EKG,Aritma, ST Segment Level, Solunum, Systolic, Diastolic, Rate, Ka\u00e7ak, Cut-off, Performans, Dinamik Bas\u0131n\u00e7, S\u0131cakl\u0131k, Invaziv Kan Bas\u0131nc\u0131, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"74\">HASTABA\u015eI MON\u0130T\u00d6R AMBULANS T\u0130P\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">EKG,Aritma, ST Segment Level, Solunum, Systolic, Diastolic, Rate, Ka\u00e7ak, Cut-off, Performans, Dinamik Bas\u0131n\u00e7, S\u0131cakl\u0131k, Invaziv Kan Bas\u0131nc\u0131, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">HAVA MANOMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">HOTPACK KAZANI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">HOTPACK KAZANI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">H\u00dcCRE GALVAN\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">\u0130NF\u00dcZYON POMPASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u0130NF\u00dcZYON POMPASI SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u0130NK\u00dcBAT\u00d6R C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ISI NEM \u00d6L\u00c7ER MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Nem (Rh)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ISI NEM \u00d6L\u00c7ER D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Nem (Rh)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">I\u015eIK KAYNA\u011eI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">I\u015f\u0131k(Lux), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u0130LA\u00c7 DOLABI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u0130LA\u00c7 DOLABI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">\u0130LA\u00c7 POMPASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u0130LA\u00c7 POMPASI SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KALP-AKC\u0130\u011eER POMPASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Ak\u0131\u015f &#8211; Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KAN SAKLAMA DOLABI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KAN SAKLAMA DOLABI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KANTAR MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KANTAR D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KEM\u0130K DANS\u0130TOMETR\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KEROTOMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KISA DALGA D\u0130ADERM\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TEM\u0130Z ODA VAL\u0130DASYON Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Partik\u00fcl Konsantrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"118\">3\/6\/12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KOMB\u0130NE ELEKTROTERAP\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">KULAKTAN ISI \u00d6L\u00c7ER Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">K\u00dcV\u00d6Z Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k, Nem, G\u00fcr\u00fclt\u00fc, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">K\u00dcV\u00d6Z TRANSPORT Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k, Nem, G\u00fcr\u00fclt\u00fc, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">LASER ULTRASOUND Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">LENSMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">MAMOGRAF\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs, G\u00f6r\u00fcnt\u00fc do\u011frulama<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">MERKEZ\u0130 S\u0130STEM ASP\u0130RAT\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7 (T\u00fcm Bas\u0131n\u00e7 Parametrelerinde, G\u00f6stergenin birimine ba\u011fl\u0131 olarak &#8211; 24 farkl\u0131 birimde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">MERKEZ\u0130 OKS\u0130JEN S\u0130STEM\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow (Litre\/Dk)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">MERKEZ\u0130 VAKUM S\u0130STEM\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7 (T\u00fcm Bas\u0131n\u00e7 Parametrelerinde, G\u00f6stergenin birimine ba\u011fl\u0131 olarak &#8211; 24 farkl\u0131 birimde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">MEZUR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">MORG DOLABI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">M\u0130KROB\u0130YOLOJ\u0130K G\u00dcVENL\u0130K KAB\u0130N\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Partik\u00fcl \u00d6l\u00e7\u00fcm\u00fc, Downflow &#8211; \u0130nflow Hava H\u0131z\u0131(m\/sn), Uv \u015eiddeti, I\u015f\u0131k \u015eiddeti, G\u00fcr\u00fclt\u00fc Testi (dB)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">M\u0130KRO P\u0130PET Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">NEB\u00dcL\u0130ZAT\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">NST C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">ODYOMETR\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OKS\u0130JEN FLOWMETRE SAB\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow (Litre\/Dk)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OKS\u0130JEN FLOWMETRE SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow (Litre\/Dk)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">OKS\u0130JEN MANOMETRE SAB\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7 (T\u00fcm Bas\u0131n\u00e7 Parametrelerinde, G\u00f6stergenin birimine ba\u011fl\u0131 olarak &#8211; 24 farkl\u0131 birimde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">OKS\u0130JEN MANOMETRE SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7 (T\u00fcm Bas\u0131n\u00e7 Parametrelerinde, G\u00f6stergenin birimine ba\u011fl\u0131 olarak &#8211; 24 farkl\u0131 birimde)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OKS\u0130JEN KONSANTRAT\u00d6R\u00dc Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow (Litre\/Dk), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OTOKLAV Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">DATA Loger \u00f6l\u00e7\u00fcm\u00fc ile S\u0131cakl\u0131k, Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OTOMAT\u0130K P\u0130PET Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OTOMAT\u0130K P\u0130PET TEKRARLAYICILI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (ml,Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">OXYLATOR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PACEMAKER C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PARAF\u0130N KAZANI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PARAF\u0130N KAZANI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">PERF\u00dcZ\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PERF\u00dcZ\u00d6R SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PH METRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Conductivity, Ph<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PN\u00d6MAT\u0130K TURN\u0130KE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">PULSEOKS\u0130METRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">O2 Saturasyonu, Nab\u0131z<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">RADAR C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">RADYANT ISITICI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">RADYOFREKANS C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">REFRAKTOMETRE C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">RESP\u0130RAT\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Solunum H\u0131z\u0131, Dakika Hacim, Tidal Hacim, PIF, PEF, Ak\u0131\u015f, PEEP, Insp Zaman\u0131, Exp Zaman\u0131, I:E Oran\u0131 &amp;PIP, MAP&amp; IPP&amp; FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance, Rate, Cut-off, Performans, Dinamik Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">R\u00d6NTGEN Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, HVL, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs, G\u00f6r\u00fcnt\u00fc \u00c7\u00f6z\u00fcn\u00fcrl\u00fck Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"56\">R\u00d6NTGEN SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">kVp do\u011frulu\u011fu, HVL, doz kararl\u0131l\u0131\u011f\u0131, doz-mAs ili\u015fkisi, kVp-doz ili\u015fkisi, mAs, G\u00f6r\u00fcnt\u00fc \u00c7\u00f6z\u00fcn\u00fcrl\u00fck Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">R\u00d6NTGEN BANYO C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k , Zaman, Densite<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SANTR\u0130F\u00dcJ Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Devir (rpm), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SANTR\u0130F\u00dcJ HEMOTOKR\u0130T Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Devir (rpm), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SANTR\u0130F\u00dcJ SO\u011eUTMALI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Devir (rpm), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SANTR\u0130F\u00dcJ Y\u00dcKSEK DEV\u0130RL\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Devir (rpm), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SEDYE BASK\u00dcL\u00dc Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SO\u011eUK BUHAR ALET\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SO\u011eUK I\u015eIK KAYNA\u011eI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">SO\u011eUK ODA TERMOMETRES\u0130 MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">SO\u011eUK ODA TERMOMETRES\u0130 D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">SOLUNUM FONKS\u0130YON TEST C\u0130HAZI (SFT) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Hacim (Lt)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">STER\u0130L\u0130ZAT\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">SU BANYOSU Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">\u015eIRINGA POMPASI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">\u015eIRINGA POMPASI SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Flow + Bas\u0131n\u00e7 + T\u0131kan\u0131kl\u0131k<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TENS C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Ak\u0131m ( mA-A), Frekans (Hz)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">TANS\u0130YON ALET\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">NIBP, Systolic, Diastolic, Rate, Cut-off, Ka\u00e7ak testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"38\">TANS\u0130YON HOLTER Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">NIBP, Systolic, Diastolic, Rate, Cut-off, Ka\u00e7ak testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TARTI MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TARTI D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TARTI-BOY-K\u0130LO MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TARTI-BOY-K\u0130LO D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TERAZ\u0130 MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TERAZ\u0130 D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k ( mg,g,Kg)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TERMOMETRE MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TERMOMETRE D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F )<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">THERMOHIGROMETRE MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Nem (Rh)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">THERMOHIGROMETRE D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Nem (Rh)<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">T\u0130MPONOMETR\u0130 Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TOMOGRAF\u0130 C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Performans Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TONOMETRE C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TRAKS\u0130YON C\u0130HAZI &#8211; BEL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TRAKS\u0130YON C\u0130HAZI &#8211; BOYUN Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">A\u011f\u0131rl\u0131k, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">TURN\u0130KE C\u0130HAZI Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">ULTRASONOGRAF\u0130 (USG) Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">T\u00fcm problar\u0131n (Konveks,Lineer,Vajinal) homojeniteleri, G\u00f6r\u00fcnt\u00fc derinli\u011fi, Uzakl\u0131k do\u011frulu\u011fu, Aksiyel ve Lateral ay\u0131rma g\u00fcc\u00fc, \u00d6l\u00fc b\u00f6lge testi ve kistik yap\u0131 g\u00f6r\u00fcnt\u00fcleme, Performans Testi, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">VAKUMMETRE Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Vakum Do\u011fruluk<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">VAPOR\u0130ZAT\u00d6R<\/td>\n<td class=\"xl65\" width=\"269\">Anestezik Gaz<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">VENT\u0130LAT\u00d6R Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Solunum H\u0131z\u0131, Dakika Hacim, Tidal Hacim, PIF, PEF, Ak\u0131\u015f, PEEP, Insp Zaman\u0131, Exp Zaman\u0131, I:E Oran\u0131 &amp;PIP, MAP&amp; IPP&amp; FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance, Rate, Cut-off, Performans, Dinamik Bas\u0131n\u00e7, Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"93\">VENT\u0130LAT\u00d6R SEYYAR Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">Solunum H\u0131z\u0131, Dakika Hacim, Tidal Hacim, PIF, PEF, Ak\u0131\u015f, PEEP, Insp Zaman\u0131, Exp Zaman\u0131, I:E Oran\u0131 &amp;PIP, MAP&amp; IPP&amp; FIO2, Is\u0131, Bas\u0131n\u00e7, Compliance, Rate, Cut-off, Performans, Dinamik Bas\u0131n\u00e7<\/td>\n<td class=\"xl65\" width=\"118\">6 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">WHIRPOOL Buzdolab\u0131 MANUAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<tr>\n<td class=\"xl65\" width=\"314\" height=\"20\">WHIRPOOL Buzdolab\u0131 D\u0130J\u0130TAL Kalibrasyon \u00d6l\u00e7\u00fcm\u00fc<\/td>\n<td class=\"xl65\" width=\"269\">S\u0131cakl\u0131k ( \u00b0C, \u00b0F ), Elektriksel G\u00fcvenlik Testi<\/td>\n<td class=\"xl65\" width=\"118\">12 Ay<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Detayl\u0131 bilgi i\u00e7in a\u015fa\u011f\u0131daki \u0130leti\u015fim Formunu mesaj\u0131n\u0131z ile birlikte g\u00f6nderiniz.<\/p>\n<div class=\"everest-forms\"><div class=\"evf-container default\" id=\"evf-701\"><form id=\"evf-form-701\" class=\"everest-form\" data-formid=\"701\" data-ajax_submission=\"0\" data-keyboard_friendly_form=\"0\" data-form_state_type=\"\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/TR\/wp-json\/wp\/v2\/posts\/131\"><div class=\"evf-field-container\"><input type=\"hidden\" id=\"_wpnonce701\" name=\"_wpnonce701\" value=\"f5c4b08f82\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/TR\/wp-json\/wp\/v2\/posts\/131\" \/><div class=\"evf-frontend-row\" data-row=\"row_1\" conditional_rules=\"[]\"><div class=\"evf-frontend-grid evf-grid-1\" data-grid=\"grid_1\"><div id=\"evf-701-field_fullname-container\" class=\"evf-field evf-field-text form-row validate-required\" data-required-field-message=\"Bu alan doldurulmal\u0131d\u0131r.\" data-field-id=\"fullname\"><label class=\"evf-field-label\" for=\"evf-701-field_fullname\"><span class=\"evf-label\">Ad Soyad<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><input type=\"text\" id=\"evf-701-field_fullname\" class=\"input-text\" name=\"everest_forms[form_fields][fullname]\" required><\/div><div id=\"evf-701-field_j6gOzOsWSA-2-container\" class=\"evf-field evf-field-text form-row validate-required\" data-required-field-message=\"Bu alan doldurulmal\u0131d\u0131r.\" data-field-id=\"j6gOzOsWSA-2\"><label class=\"evf-field-label\" for=\"evf-701-field_j6gOzOsWSA-2\"><span class=\"evf-label\">Kurum Ad\u0131<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><input type=\"text\" id=\"evf-701-field_j6gOzOsWSA-2\" class=\"input-text\" name=\"everest_forms[form_fields][j6gOzOsWSA-2]\" required><\/div><div id=\"evf-701-field_email-container\" class=\"evf-field evf-field-email form-row validate-required validate-email\" data-required-field-message=\"Ge\u00e7erli bir ePosta adresi giriniz.\" data-field-id=\"email\"><label class=\"evf-field-label\" for=\"evf-701-field_email\"><span class=\"evf-label\">ePosta<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><input type=\"email\" id=\"evf-701-field_email\" class=\"input-text\" name=\"everest_forms[form_fields][email]\" required ><\/div><div id=\"evf-701-field_vsEd4GhcPV-3-container\" class=\"evf-field evf-field-text form-row validate-required\" data-required-field-message=\"Bu alan doldurulmal\u0131d\u0131r.\" data-field-id=\"vsEd4GhcPV-3\"><label class=\"evf-field-label\" for=\"evf-701-field_vsEd4GhcPV-3\"><span class=\"evf-label\">Telefon<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><input type=\"text\" id=\"evf-701-field_vsEd4GhcPV-3\" class=\"input-text\" name=\"everest_forms[form_fields][vsEd4GhcPV-3]\" required><\/div><div id=\"evf-701-field_subject-container\" class=\"evf-field evf-field-text form-row validate-required\" data-required-field-message=\"Bu alan doldurulmal\u0131d\u0131r.\" data-field-id=\"subject\"><label class=\"evf-field-label\" for=\"evf-701-field_subject\"><span class=\"evf-label\">Konu<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><input type=\"text\" id=\"evf-701-field_subject\" class=\"input-text\" name=\"everest_forms[form_fields][subject]\" required><\/div><div id=\"evf-701-field_message-container\" class=\"evf-field evf-field-textarea form-row validate-required\" data-required-field-message=\"Bu alan doldurulmal\u0131d\u0131r.\" data-field-id=\"message\"><label class=\"evf-field-label\" for=\"evf-701-field_message\"><span class=\"evf-label\">Mesaj\u0131n\u0131z<\/span> <abbr class=\"required\" title=\"Required\">*<\/abbr><\/label><textarea id=\"evf-701-field_message\" class=\"input-text\" name=\"everest_forms[form_fields][message]\" required ><\/textarea><\/div><\/div><\/div><\/div><div class=\"evf-honeypot-container evf-field-hp\"><label for=\"evf-701-field-hp\" class=\"evf-field-label\">Name<\/label><input type=\"text\" name=\"everest_forms[hp]\" id=\"evf-701-field-hp\" class=\"input-text\"><\/div><div class=\"evf-recaptcha-container \" style=\"display:block\"><div class=\"g-recaptcha\" data-sitekey=\"6LeTKncUAAAAABSyiVfgtBE5uxWPTjRGnggqyxfx\"><\/div><\/div><div class=\"evf-submit-container \" ><input type=\"hidden\" name=\"everest_forms[id]\" value=\"701\"><input type=\"hidden\" name=\"everest_forms[author]\" value=\"18\"><button type='submit' name='everest_forms[submit]' class='everest-forms-submit-button button evf-submit ' id='evf-submit-701' value='evf-submit' data-process-text=\"G\u00f6nderiliyor\u2026\" conditional_rules='&quot;&quot;' conditional_id='evf-submit-701'  id=\"evf-submit-701\" aria-live=\"assertive\">G\u00f6nder<\/button><\/div><\/form><\/div><!-- .evf-container --><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Biyomedikal Kalibrasyon Kapsam Medibim; Biyomedikal Kalibrasyon \u00d6l\u00e7\u00fcm Hizmetlerinde sekt\u00f6r\u00fcn lideri bir firma olarak,\u00a0 TS EN ISO standartlar\u0131 AAPM IPEM WHO<\/p>\n","protected":false},"author":18,"featured_media":72,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"colormag_page_container_layout":"default_layout","colormag_page_sidebar_layout":"default_layout","footnotes":""},"categories":[29],"tags":[134,874,1033],"class_list":["post-131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-biyomedikal-metroloji","tag-biyomedikal-metroloji","tag-kapsam","tag-tibbi-cihaz-kalibrasyon"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon<\/title>\n<meta name=\"description\" content=\"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon\" \/>\n<meta property=\"og:description\" content=\"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/\" \/>\n<meta property=\"og:site_name\" content=\"Medibim Biyomedikal Metroloji ve Kalibrasyon\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/medibim\" \/>\n<meta property=\"article:published_time\" content=\"2017-08-03T09:29:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-20T15:38:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"572\" \/>\n\t<meta property=\"og:image:height\" content=\"318\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"medibim\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@medibim\" \/>\n<meta name=\"twitter:site\" content=\"@medibim\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"medibim\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"17 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/\"},\"author\":{\"name\":\"medibim\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#\\\/schema\\\/person\\\/a4ff9d43f488c54da9fe049edfeb40d4\"},\"headline\":\"Biyomedikal Kalibrasyon Kapsam\",\"datePublished\":\"2017-08-03T09:29:37+00:00\",\"dateModified\":\"2023-10-20T15:38:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/\"},\"wordCount\":3341,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2013\\\/07\\\/04-oper-e1539694954760.jpg\",\"keywords\":[\"biyomedikal metroloji\",\"kapsam\",\"t\u0131bbi cihaz kalibrasyon\"],\"articleSection\":[\"Biyomedikal Metroloji\"],\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/\",\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/\",\"name\":\"Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2013\\\/07\\\/04-oper-e1539694954760.jpg\",\"datePublished\":\"2017-08-03T09:29:37+00:00\",\"dateModified\":\"2023-10-20T15:38:15+00:00\",\"description\":\"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2013\\\/07\\\/04-oper-e1539694954760.jpg\",\"contentUrl\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2013\\\/07\\\/04-oper-e1539694954760.jpg\",\"width\":572,\"height\":318},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/biyomedikal-metroloji\\\/biyomedikal-kalibrasyon-kapsam\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana sayfa\",\"item\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Biyomedikal Kalibrasyon Kapsam\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#website\",\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/\",\"name\":\"Medibim Biyomedikal Metroloji ve Kalibrasyon\",\"description\":\"Test Muayene Kalibrasyon Validasyon Kalibrat\u00f6r E\u011fitim\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#organization\",\"name\":\"Medibim Biyomedikal\",\"alternateName\":\"Biyomedikal Metroloji ve Kalibrasyon Hizmetleri\",\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/medibim-logo-150x72-72dpi.png\",\"contentUrl\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/medibim-logo-150x72-72dpi.png\",\"width\":150,\"height\":72,\"caption\":\"Medibim Biyomedikal\"},\"image\":{\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/medibim\",\"https:\\\/\\\/x.com\\\/medibim\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/medibim-biyomedikal-metroloji-bb952059\\\/\",\"https:\\\/\\\/www.facebook.com\\\/medibim-biyomedikal\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/#\\\/schema\\\/person\\\/a4ff9d43f488c54da9fe049edfeb40d4\",\"name\":\"medibim\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g\",\"caption\":\"medibim\"},\"url\":\"https:\\\/\\\/www.medibim.com.tr\\\/TR\\\/author\\\/medibim\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon","description":"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/","og_locale":"tr_TR","og_type":"article","og_title":"Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon","og_description":"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi","og_url":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/","og_site_name":"Medibim Biyomedikal Metroloji ve Kalibrasyon","article_publisher":"https:\/\/www.facebook.com\/medibim","article_published_time":"2017-08-03T09:29:37+00:00","article_modified_time":"2023-10-20T15:38:15+00:00","og_image":[{"width":572,"height":318,"url":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg","type":"image\/jpeg"}],"author":"medibim","twitter_card":"summary_large_image","twitter_creator":"@medibim","twitter_site":"@medibim","twitter_misc":{"Yazan:":"medibim","Tahmini okuma s\u00fcresi":"17 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#article","isPartOf":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/"},"author":{"name":"medibim","@id":"https:\/\/www.medibim.com.tr\/TR\/#\/schema\/person\/a4ff9d43f488c54da9fe049edfeb40d4"},"headline":"Biyomedikal Kalibrasyon Kapsam","datePublished":"2017-08-03T09:29:37+00:00","dateModified":"2023-10-20T15:38:15+00:00","mainEntityOfPage":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/"},"wordCount":3341,"commentCount":0,"publisher":{"@id":"https:\/\/www.medibim.com.tr\/TR\/#organization"},"image":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#primaryimage"},"thumbnailUrl":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg","keywords":["biyomedikal metroloji","kapsam","t\u0131bbi cihaz kalibrasyon"],"articleSection":["Biyomedikal Metroloji"],"inLanguage":"tr","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/","url":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/","name":"Biyomedikal Kalibrasyon Kapsam - Medibim Biyomedikal Metroloji ve Kalibrasyon","isPartOf":{"@id":"https:\/\/www.medibim.com.tr\/TR\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#primaryimage"},"image":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#primaryimage"},"thumbnailUrl":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg","datePublished":"2017-08-03T09:29:37+00:00","dateModified":"2023-10-20T15:38:15+00:00","description":"Biyomedikal Kalibrasyon Kapsam, Kalibrasyon periyotlar\u0131, risk derecesi","breadcrumb":{"@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#primaryimage","url":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg","contentUrl":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2013\/07\/04-oper-e1539694954760.jpg","width":572,"height":318},{"@type":"BreadcrumbList","@id":"https:\/\/www.medibim.com.tr\/TR\/biyomedikal-metroloji\/biyomedikal-kalibrasyon-kapsam\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana sayfa","item":"https:\/\/www.medibim.com.tr\/TR\/"},{"@type":"ListItem","position":2,"name":"Biyomedikal Kalibrasyon Kapsam"}]},{"@type":"WebSite","@id":"https:\/\/www.medibim.com.tr\/TR\/#website","url":"https:\/\/www.medibim.com.tr\/TR\/","name":"Medibim Biyomedikal Metroloji ve Kalibrasyon","description":"Test Muayene Kalibrasyon Validasyon Kalibrat\u00f6r E\u011fitim","publisher":{"@id":"https:\/\/www.medibim.com.tr\/TR\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.medibim.com.tr\/TR\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/www.medibim.com.tr\/TR\/#organization","name":"Medibim Biyomedikal","alternateName":"Biyomedikal Metroloji ve Kalibrasyon Hizmetleri","url":"https:\/\/www.medibim.com.tr\/TR\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.medibim.com.tr\/TR\/#\/schema\/logo\/image\/","url":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2018\/10\/medibim-logo-150x72-72dpi.png","contentUrl":"https:\/\/www.medibim.com.tr\/TR\/wp-content\/uploads\/2018\/10\/medibim-logo-150x72-72dpi.png","width":150,"height":72,"caption":"Medibim Biyomedikal"},"image":{"@id":"https:\/\/www.medibim.com.tr\/TR\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/medibim","https:\/\/x.com\/medibim","https:\/\/www.linkedin.com\/in\/medibim-biyomedikal-metroloji-bb952059\/","https:\/\/www.facebook.com\/medibim-biyomedikal"]},{"@type":"Person","@id":"https:\/\/www.medibim.com.tr\/TR\/#\/schema\/person\/a4ff9d43f488c54da9fe049edfeb40d4","name":"medibim","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/secure.gravatar.com\/avatar\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1fc9c03014482fd7ddcbbd5f7b6deca9e040ed6690a2fed9fa182dbe8ef7280b?s=96&d=mm&r=g","caption":"medibim"},"url":"https:\/\/www.medibim.com.tr\/TR\/author\/medibim\/"}]}},"_links":{"self":[{"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/posts\/131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/comments?post=131"}],"version-history":[{"count":15,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/posts\/131\/revisions"}],"predecessor-version":[{"id":1750,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/posts\/131\/revisions\/1750"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/media\/72"}],"wp:attachment":[{"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/media?parent=131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/categories?post=131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.medibim.com.tr\/TR\/wp-json\/wp\/v2\/tags?post=131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}